Vol. 119
Latest Volume
All Volumes
PIER 180 [2024] PIER 179 [2024] PIER 178 [2023] PIER 177 [2023] PIER 176 [2023] PIER 175 [2022] PIER 174 [2022] PIER 173 [2022] PIER 172 [2021] PIER 171 [2021] PIER 170 [2021] PIER 169 [2020] PIER 168 [2020] PIER 167 [2020] PIER 166 [2019] PIER 165 [2019] PIER 164 [2019] PIER 163 [2018] PIER 162 [2018] PIER 161 [2018] PIER 160 [2017] PIER 159 [2017] PIER 158 [2017] PIER 157 [2016] PIER 156 [2016] PIER 155 [2016] PIER 154 [2015] PIER 153 [2015] PIER 152 [2015] PIER 151 [2015] PIER 150 [2015] PIER 149 [2014] PIER 148 [2014] PIER 147 [2014] PIER 146 [2014] PIER 145 [2014] PIER 144 [2014] PIER 143 [2013] PIER 142 [2013] PIER 141 [2013] PIER 140 [2013] PIER 139 [2013] PIER 138 [2013] PIER 137 [2013] PIER 136 [2013] PIER 135 [2013] PIER 134 [2013] PIER 133 [2013] PIER 132 [2012] PIER 131 [2012] PIER 130 [2012] PIER 129 [2012] PIER 128 [2012] PIER 127 [2012] PIER 126 [2012] PIER 125 [2012] PIER 124 [2012] PIER 123 [2012] PIER 122 [2012] PIER 121 [2011] PIER 120 [2011] PIER 119 [2011] PIER 118 [2011] PIER 117 [2011] PIER 116 [2011] PIER 115 [2011] PIER 114 [2011] PIER 113 [2011] PIER 112 [2011] PIER 111 [2011] PIER 110 [2010] PIER 109 [2010] PIER 108 [2010] PIER 107 [2010] PIER 106 [2010] PIER 105 [2010] PIER 104 [2010] PIER 103 [2010] PIER 102 [2010] PIER 101 [2010] PIER 100 [2010] PIER 99 [2009] PIER 98 [2009] PIER 97 [2009] PIER 96 [2009] PIER 95 [2009] PIER 94 [2009] PIER 93 [2009] PIER 92 [2009] PIER 91 [2009] PIER 90 [2009] PIER 89 [2009] PIER 88 [2008] PIER 87 [2008] PIER 86 [2008] PIER 85 [2008] PIER 84 [2008] PIER 83 [2008] PIER 82 [2008] PIER 81 [2008] PIER 80 [2008] PIER 79 [2008] PIER 78 [2008] PIER 77 [2007] PIER 76 [2007] PIER 75 [2007] PIER 74 [2007] PIER 73 [2007] PIER 72 [2007] PIER 71 [2007] PIER 70 [2007] PIER 69 [2007] PIER 68 [2007] PIER 67 [2007] PIER 66 [2006] PIER 65 [2006] PIER 64 [2006] PIER 63 [2006] PIER 62 [2006] PIER 61 [2006] PIER 60 [2006] PIER 59 [2006] PIER 58 [2006] PIER 57 [2006] PIER 56 [2006] PIER 55 [2005] PIER 54 [2005] PIER 53 [2005] PIER 52 [2005] PIER 51 [2005] PIER 50 [2005] PIER 49 [2004] PIER 48 [2004] PIER 47 [2004] PIER 46 [2004] PIER 45 [2004] PIER 44 [2004] PIER 43 [2003] PIER 42 [2003] PIER 41 [2003] PIER 40 [2003] PIER 39 [2003] PIER 38 [2002] PIER 37 [2002] PIER 36 [2002] PIER 35 [2002] PIER 34 [2001] PIER 33 [2001] PIER 32 [2001] PIER 31 [2001] PIER 30 [2001] PIER 29 [2000] PIER 28 [2000] PIER 27 [2000] PIER 26 [2000] PIER 25 [2000] PIER 24 [1999] PIER 23 [1999] PIER 22 [1999] PIER 21 [1999] PIER 20 [1998] PIER 19 [1998] PIER 18 [1998] PIER 17 [1997] PIER 16 [1997] PIER 15 [1997] PIER 14 [1996] PIER 13 [1996] PIER 12 [1996] PIER 11 [1995] PIER 10 [1995] PIER 09 [1994] PIER 08 [1994] PIER 07 [1993] PIER 06 [1992] PIER 05 [1991] PIER 04 [1991] PIER 03 [1990] PIER 02 [1990] PIER 01 [1989]
2011-08-10
Validation of a Numerical Approach to the Analysis of a Live-Line Worker Exposure to the Electric Field
By
Progress In Electromagnetics Research, Vol. 119, 315-333, 2011
Abstract
The aim of this paper is to validate a proposed simplified boundary-integral approach (that is called here LEM&BEM) for the analysis of electric field in a live-line-working zone. A human body model of a simplified geometry that is applied to the electric field estimation around the live-line worker is also tested. Numerical results of a more accurate numerical approach, laboratory measurements as well as results of measurements taken on a real tower of HV overhead line are employed for this purpose. The numerical analysis of the electric field distribution in the hot-stick working zone on an anchor tower of 400 kV transmission line is presented to demonstrate the effectiveness of the numerical technique under consideration. The author's own software packages has been applied in computations.
Citation
Wojciech Krajewski, "Validation of a Numerical Approach to the Analysis of a Live-Line Worker Exposure to the Electric Field," Progress In Electromagnetics Research, Vol. 119, 315-333, 2011.
doi:10.2528/PIER11060501
References

1. Stuchly, M. A. and S. Zhao, "Magnetic field-induced currents in human body in proximity of power lines," IEEE Trans. on Power Delivery, Vol. 11, No. 1, 102-108, 1996.
doi:10.1109/61.484005

2. Dawson, T. W., K. Caputa, and M. Stuchly, "Magnetic field exposure for UK live-line workers," Physics in Medicine and Biology, Vol. 47, 995-1012, 2002.
doi:10.1088/0031-9155/47/7/301

3. Cherubini, E., N. Chavannes, and N. Kuster, "Realistic skeleton based deformation of high-resolution anatomical human models for electromagnetic simulation," The 31st Annual Meeting of the Bioelectromagnetic Society, 2009.

4. Hirata, A., H. Sugiyama, and O. Fujiwara, "Estimation of core temperature elevation in humans and animals for whole-body averaged SAR ," Progress In Electromagnetics Research, Vol. 99, 53-70, 2009.
doi:10.2528/PIER09101603

5. Chou, H.-H., H.-T. Hsu, H.-T. Chou, K.-H. Liu, and F.-Y. Kuo, "Reduction of peak SAR in human head for handset applications with resistive sheets (r-cards)," Progress In Electromagnetics Research, Vol. 94, 281-296, 2009.
doi:10.2528/PIER09062702

6. Gemio, J., J. Parron, and J. Soler, "Human body effects on implantable antennas for ism bands applications: models comparison and propagation losses study," Progress In Electromagnetics Research, Vol. 110, 437-452, 2010.
doi:10.2528/PIER10102604

7. Sabbah, A. I., N. I. Dib, and M. A. Al-Nimr, "SAR and temperature elevation in a multi-layered human head model due to an obliquely incident plane wave," Progress In Electromagnetics Research M, Vol. 13, 95-108, 2010.
doi:10.2528/PIERM10051502

8. Krajewski, W., "Numerical assessment of electromagnetic exposure during live-line works on high-voltage objects," IEE Proc. Science, Measurement and Technology, Vol. 3, No. 1, 27-38, 2009.
doi:10.1049/iet-smt:20080070

9. Krajewski, W., "Numerical evaluation of the magnetic field exposure near the transition tower of an overhead-underground HV line," Progress In Electromagnetics Research M, Vol. 14, 247-261, 2010.
doi:10.2528/PIERM10101102

10. "Directive 2004/40/EC of the European Parliament and of the Council of 29 April 2004 on the minimum health and safety requirements regarding the exposure of workers to the risk arising from physical agents (electromagnetic fields) (18th individual Directive 89/391/EEC)," Official Journal of the European Union, Nr L-184, 1-9, 2004.

11. International Commission on Non-Ionizing Radiation Protection (ICNIRP) "Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz) ," Health Physics, Vol. 74, No. 4, 494-522, 1998.

12. International Commission on Non-Ionizing Radiation Protection (ICNIRP) "Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz) ," Health Physics, Vol. 99, No. 6, 818-836, 2010.

13. Brebbia, C. A., J. C. F. Telles, and L. C. Wrobel, Boundary Element Techniques, Springer, Berlin, Heidelberg, New York, 1984.

14. Singer, H., H. Steinbigler, and P. Weiss, "A charge simulation method for the calculation of high voltage fields," IEEE Trans. on Power Apparatus and Systems, Vol. 93, 1660-1668, 1973.

15. Rankovic, A. and M. S. Savic, "Generalized charge simulation method for the calculation of the electric field in high voltage substations," Electrical Engineering (Archiv fur Elektrotechnik), Vol. 92, No. 2, 69-77, 2010.
doi:10.1007/s00202-010-0161-7

16. Krajewski, W., "Boundary and line elements in the analysis of selected EMC problems of low frequency," Prace Instytut Elektrotechniki (Proceedings of Electrotechnical Institute), Zeszyt 224, 2005 (Monograph in Polish).

17. Krajewski, W., "Numerical modelling of the electric field in HV substations," IEE Proc. Science, Measurement and Technology, Vol. 151, No. 4, 267-272, 2004.
doi:10.1049/ip-smt:20040565

18. IEC/EN 62233, , Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure , International Electrotechnical Commission, Geneva, 2005.

19. Lopatkiewicz, R., Z. Nadolny, and A. Rakowska, "Analysis of electric field intensity during live maintenance on 400 kV overhead power transmission line," Przagl»ad Elektrotechniczny (Electrical Review), Vol. 11b, 258-261, 2010 (in Polish).